Spn 1347 fmi 3

Fault Code: 281. PID (P), SID (S): S126. SPN: 1347. FMI: 7. Lamp: Amber. REASON: Fuel Pump Pressurizing Assembly 1 - Mechanical System Not Responding Properly or Out of Adjustment. A pumping imbalance between the front and rear pumping plungers has been. detected. EFFECT: Engine will not run or possible low power..

Fault Code: 281. PID (P), SID (S): S126. SPN: 1347. FMI: 7. SRT: REASON: Fuel Pump Pressurizing Assembly 1 - Mechanical System Not Responding Properly or Out of Adjustment. EFFECT: Engine will NOT run or possible low power. Circuit Description: The fuel pump contains two barrel and plunger assemblies; each barrel and plunger assembly utilizes ...SPN 1347 FMI 6 Fuel Pump Relay Coil Short to Power 204 SPN 1348 FMI 5 Fuel Pump Relay Coil Open 198 SPN 1485 FMI 3 Power Relay Coil Short to Power 222 SPN 1485 FMI 4 Power Relay Ground Short 220 SPN 1485 FMI 5 Power Relay Coil Open 218 SPN 3050 FMI 11 Catalyst Inactive on Gasoline (Bank1) 161 SPN 3051 FMI 11 Catalyst Inactive on …

Did you know?

SPN 1347 FMI 6 Fuel Pump Relay Coil Short to Power 204 SPN 1348 FMI 5 Fuel Pump Relay Coil Open 198 SPN 1485 FMI 3 Power Relay Coil Short to Power 222 SPN 1485 …Jun 13, 2019 · I have a 2012 Kenworth T600 with Cummins isx. Yesterday morning, it started getting the code SPN 1347 FMI 3. The code went away last night and hasn't come back. I looked it up on Cummins insite so I k … read more Home / DTC TRUCKS / Cumminz / X12 CM2350 X119B (2018 & Newer) / Cummins X12 CM2350 X119B (2018 & Newer) Fault Code: 272 PID: SID 126 SPN: 1347 FMI: 3 Engine Fuel Pump PRessurizing Assembly 1 Circuit- Voltage Above Normal or Shorted to High Source

SPN 1321, FMI 3 - Start Relay Coil . Page 189 and 190: SPN 1348, FMI 5 - Fuel Pump Relay C. Page 191 and 192: SPN 1347, FMI 5 - Fuel Pump Relay G. Page 193 and 194: SPN 1347, FMI 6 - Fuel Pump Relay C. Page 195 and 196: SPN 1213, FMI 5 - MIL Open Key On, Page 197 and 198: SPN 515, FMI 16 - RPM Above Fuel Re. Page 199 and 200:Check for multiple codes. If 1176/3, 1172/3, 100/3 and 175/3 are present, repair the open between pin 105 on the 120-pin MCM connector and the associated sensors. Refer to "88.2.1.1 Verify Repairs" . If 1176/3 and 1172/3 are present, go to step 7 . If only 1176/2 is present, go to step 4 . Turn the ignition OFF.SPN#1347, FMI#3 ― High Voltage or Open Circuit At Fuel Pump Actuator -- Continued. MALFUNCTION. TEST OR INSPECTION. CORRECTIVE ACTION. 8. Pin-to-pin short circuit in engine. 1. Measure resistance between. 1. If resistance is more than 100. ECM wiring harness. fuel pump actuator SIGNAL pin. kiloOhms (kΩ), proceed to next.Page 193 and 194: SPN 1347, FMI 6 - Fuel Pump Relay C; Page 195 and 196: SPN 1213, FMI 5 - MIL Open Key On, ... SPN 91, FMI 3 - FPP1 Voltage High F. Page 295 and 296: SPN 520199, FMI11 - FPP2 Invalid Vo. Page 297 and 298: SPN 91, FMI 16 - FPP1 Higher than F. Page 299 and 300:

Page 193 and 194: SPN 1347, FMI 6 - Fuel Pump Relay C; Page 195: SPN 1213, FMI 5 - MIL Open Key On, Page 199 and 200: SPN 515, FMI 0 - RPM Above Spark Re; ... SPN 91, FMI 3 - FPP1 Voltage High F. Page 295 and 296: SPN 520199, FMI11 - FPP2 Invalid Vo. Page 297 and 298: SPN 91, FMI 16 - FPP1 Higher than F.SPN 3216 (ACM) (EPA10;GHG14) September 2014 Additions, Revisions, or Updates Publication Number / Title Platform Section Title Change DDC-SVC-MAN-0084 EPA10/ GHG14 DD Platform SPN 3216/FMI 3 - EPA10 - GHG14 This is an updated section to reflect fault monitor sequence. SPN 3216/FMI 4 - EPA10 - GHG14 9 03-14 All information …Dec 15, 2013. #1. I have a IR G 240 generator. When i load bank the unit and get about 150 kw of load the rpm starts to fall and i get a spn 1347 fmi 7 code. I have changed the mechanical fuel pump and the high press pump also the press sensor on the fuel rail with out success. Also checked the relief valve on the rail for leakage when running ... ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Spn 1347 fmi 3. Possible cause: Not clear spn 1347 fmi 3.

Section 57.1SPN 647/FMI 3. Turn the ignition OFF. Disconnect the fan control solenoid connector. Turn the ignition ON (key On, engine OFF). Measure the voltage between pin 1 of the fan control solenoid connector and ground. If the voltage is greater than 11.5 volts, repair the short to power between pin 1 of the fan control solenoid connector ...Code 1347.4 (Engine System): Here, ’13’ is indicative of the engine system, ’47’ is signaling the fuel pump, ... Separator and Header Engage Status Control Unit SPN FMI Pri. Description: C03 1567 09 3: CAN Bus message missing from Header Control Unit – Control Mode: C03 100100 09 3:

CODES: Fault Code: 2555. PID (P), SID (S): S070. SPN: 729. FMI: 3. Lamp: Amber. REASON: Intake Air Heater 1 Circuit - Voltage Above Normal or Shorted to High Source. High voltage detected at the intake air heater signal circuit. EFFECT: The intake air heaters may be ON or OFF all the time.May 18, 2022 · We have a loss of power, stalling, and hard start situations. I have replaced the fuel filter 2x in the last month. The first time after a CEL indicated a blocked fuel filter. The second time to potentially prime the engine in case there was an air gap. -SPN 157 FMI 18 = Excessive fuel flow restriction to the high pressure fuel pump. SPN 920, FMI 3 - Buzzer Control Sho. Page 285 and 286: SPN 1213, FMI 4 - MIL Control Groun. Page 287 and 288: SPN 1213, FMI 3 - MIL Control Short. Page 289 and 290: SFC 638-Throttle Unable To Close Ke. Page 291 and 292: SPN 91, FMI 18 - FPP1 Lower than FP. Page 293 and 294: SPN 91, FMI 3 - FPP1 Voltage High F. Page 295 and 296:

hydrocodone blue pill Troubleshooting information: click here. Click the link above for troubleshooting information. Ask Your Own Medium and Heavy Trucks Question. what is FMI 16? Technician: Nich M. So the 1347-16 translates to P0094. Ask Your Own Medium and Heavy Trucks Question. small leak somewhere. i must recheck my work. how long has julie chen been marriedis jennifer copeland married SPN 1177 FMI 3 Discussion in 'International Forum' started by WMGUY, Jan 30, 2022. Jan 30, 2022 #1. WMGUY Road Train Member. 1,683 799. Jan 1, 2011 Nine Mile Falls, WA 0. I have checked the harness and voltage and resistance is within spec. I'm having trouble finding the part. Does it go by another name?SPN: 1347 FMI: 3 Description: Engine Fuel Pump PRessurizing Assembly 1 Circuit- Voltage Above Normal or Shorted to High Source Troubleshooting: Circuit Description The circuit is a pulse-width modulation (PWM) driver in the engine control module (ECM) that controls the fuel pump actuator. The actuator is grounded in the ECM. maple hts police dept Apr 17, 2015. #1. Hi All. Hope you can help out. I have a 2006 8104 Tarragator that is giving me code 1347-7. Symptoms are sporadic loss of power. We can be going down the field at full power then it will start to die then recover then die again. It seems like a no fuel issue so we changed fuel filters and cleaned the tanks. kubota bx2350 parts diagramis hollow knight multiplayerpurdue student suicide 2023 Cummins X15 CM2450 X124B (2018 & Newer) Fault Code: 5793 PID: SPN: 7323 FMI: 3 Aftertreatment 1 Particulate Sensor Heater Low Side Driver Circuit- Voltage Above Normal or Shorted to High Source. Circuit Description The aftertreatment particulate matter sensor is a smart device and communicates with the engine control module (ECM) via the J1939 ...Product Downloads. y Product Declaration of Conformity. y Data Sheet. y Data Sheet (US) y 72/73 Operators Manual (Japanese) y DSE72xx/DSE73xx Operators Manual. y DSE7xxx Series Operators Manual - Portuguese. y DSE72xx/DSE73xx Operators Manual - German. y Installation Instructions. i 82 road conditions yakima to ellensburg Click below for the troubleshootingFault code 94 is 4 low fuel pressure. This is likely a secondary cold resulting from the 1347 code. Troubleshoot to 1347 code and also look for fuel restrictions are leeks as well. Once the 1347 code is resolved and the troubleshooting steps made then reset and see if either codes return. who is leanbeefpattynextstellis birth control weight gainbasketball heads unblocked 3 minute read. SPN 1485, FMI 3 - Power Relay Coil Short-To-Power. from Indmar Marine Engines J1939 Code Manual - pdf download. by www.heydownloads.com. Next Article.Refer to "8.4.1 Verify Repairs" . If only fault 164/3 is active, go to the next step. Disconnect the Rail Pressure Governor Sensor connector. Measure the resistance across pins 1 and 2 of the Rail Pressure Governor Sensor. If the resistance is greater than 4.7 k Ω, replace Rail Pressure Governor Sensor.